Multi Pair Shielded Computer Cable

Multi Pair Shielded Computer Cable
Product Introduction:
The multi pair shielded computer cable answers the common problem of parallel multi-loop wiring: as channels multiply, adjacent circuits couple through a single overall shield and distort synchronized acquisition data. Each loop receives independent grouping, with overall shield added on the outside, so buyers can kit all channels for a project in one order instead of joining wires on site.
Send Inquiry
Description
Technical Parameters
Solving Crosstalk Across Many Loops
 

 

The multi pair shielded computer cable answers the common problem of parallel multi-loop wiring: as channels multiply, adjacent circuits couple through a single overall shield and distort synchronized acquisition data. Each loop receives independent grouping, with overall shield added on the outside, so buyers can kit all channels for a project in one order instead of joining wires on site. Sections cover 0.5, 0.75 and 1.0mm², with 2, 4, 6 and 8 pairs; non-standard core counts and lengths are made to order.

computer-instrument-cablecafe7

Independent Foil and Braid Layering

 

computer-instrument-cablee3363

 

Conductor is high-purity oxygen-free copper with stable conductivity; tinned copper upgrades to damp or corrosive circuits. Insulation comes in PVC or halogen-free LSZH material with reliable inter-core isolation. Independent grouping pairs foil shielding with copper braid to block interference from power cables, motors and inverters, and each channel stays separated so a fluctuation on one loop does not spread to neighboring acquisition paths. The flexible jacket bends easily for dense cabinet routing and tray laying.

Industries and Routing Positions
 

Scene one: synchronized multi-loop analog and digital upload in DCS and PLC systems across chemical, power, metallurgy, pharmaceutical and smart manufacturing plants. Scene two: grouped acquisition for temperature and pressure transmitters and precision instruments, every circuit independently shielded. Scene three: concentrated indoor cabinet wiring where group shields keep channel order clear. Scene four: parallel runs in workshop trays and cable trenches, holding stable shielding even at spacing from power cables.

computer-instrument-cablee4617

 

Custom Specs and Sample Policy

Pair count, pair core and length follow device loop numbers; section and jacket color are selectable, with matching marking and drums. Standard cable starts at 100 m, small quantities accepted, and one batch may mix models and colors with split packing at no extra charge. Non-standard pairs can start with a sample; sample fees are credited on bulk orders, regular samples about 3 working days, special material or structure 5 to 7.

QC, Packing and Terms

Raw-material sampling, precision pair twisting, shield processing and finished electrical checks run batch by batch; packing and pre-shipment review verify specs, appearance, insulation and shielding against records. Export reinforcement with drum wrapping resists long-haul squeeze and wear, marks customized on request. Standard models 3 to 5 days, custom around one week; EXW, FOB, DDP supported, standard 30% deposit with 70% balance, 1-year warranty under normal use.

 

Product Specifications

 

Parameter

Specification

Rated voltage

300/500V

Conductor section

0.5 / 0.75 / 1.0mm²

Common pairs

2, 4, 6, 8 pairs; non-standard cores custom

Shielding

Independent grouped shield + overall shield (foil / copper braid)

Insulation material

PVC or LSZH

 

 

 

Hot Tags: multi pair shielded computer cable, China multi pair shielded computer cable manufacturers, suppliers, factory, Computer and Instrument Cable, computer cables with stranded conductors, Computer Instrument Cable, continuous flex computer cables, EMC computer cables, Shielded Computer Cable