The outdoor armored computer cable targets direct burial, tunnels and pipe runs in power, metallurgy and petrochemical control systems and detection instruments at 300/500V. Above-ground routing faces soil pressure, construction rolling impact and rodent bites; an unarmored jacket cracks at the core and fails early. A metal armor layer outside conductor and insulation absorbs that force and adds some low-frequency interference suppression.
Send Inquiry
Description
Technical Parameters
Why Armor Matters Outdoors
 

 

The outdoor armored computer cable targets direct burial, tunnels and pipe runs in power, metallurgy and petrochemical control systems and detection instruments at 300/500V. Above-ground routing faces soil pressure, construction rolling impact and rodent bites; an unarmored jacket cracks at the core and fails early. A metal armor layer outside conductor and insulation absorbs that force and adds some low-frequency interference suppression.

computer-instrument-cable1dc13

Armor Forms Chosen by Force Direction

 

computer-instrument-cable53da3

 

Conductor is 99.9% high-purity oxygen-free copper for low resistance and low loss. PE insulation reaches 70℃, XLPE 90℃, and halogen-free crosslinked polyolefin runs at 90℃ or 125℃; fixed laying starts at -40℃ for outdoor day-night swings. Steel-tape armor resists radial pressure and fits direct burial, while steel-wire armor resists axial pull for shafts and vertical runs. Mesh steel wire performs better on high-frequency noise, steel tape on low-frequency magnetic fields, so selection follows both force direction and interference type.

Match the Routing Method
 

Burial or pressure locations take steel-tape armor; shafts and vertical drops take steel-wire armor. Mismatching armor to the condition wastes budget and leaves the weak point unprotected. Scene one: outdoor and underground signal lines in power monitoring dispatch, metallurgy/chemical automation and coal mine safety systems. Scene two: rail signal transmission, municipal underground network monitoring and buried smart-building wiring. Scene three: fixed positions under mechanical force, direct burial, trenches and conduit. Scene four: exposed or buried outdoor monitoring over clear temperature swings.

computer-instrument-cablea0f2d

 

Made to Order and Inspection

Models are matched to laying environment and core count/section, with special cables processed on request; marking and drums customized. Third-party on-site sampling or full inspection is accepted, with timing and standards agreed in advance. Custom orders use 50% deposit and 50% before shipment.

Production Checks and Export Packing

Raw materials are sampled on entry, key processes patrolled, and finished units tested for withstand voltage, insulation and shielding; a 100% pre-packing check confirms specs and appearance before a full report ships out. Wooden cases or pallets reinforce long-haul sea and land freight, marks on request; custom around one week, complex specs extended. EXW, FOB, DDP supported, 1-year warranty under normal use handled by after-sales.

 

Product Specifications

 

Parameter

Specification

Rated voltage

U0/U 300/500V

Insulation working temperature

PE 70℃, XLPE 90℃

Laying ambient temperature

Fixed -40℃, non-fixed -15℃

Armor form

Steel tape (22) / steel wire (32, 42)

Minimum bending radius

Armored ≥12× OD, unarmored ≥6× OD

 

 

 