Fire Alarm Control Cable

Fire Alarm Control Cable
Product Introduction:
The fire alarm control cable carries a mica fire-resistant tape that keeps power and signal alive in high heat, unlike ordinary wire that melts and breaks quickly. The structure works at 950℃ to 1000℃ open flame for over 90 minutes without short circuit, open circuit or burning, maintaining alarm and interlock communication when evacuation and rescue need time.
Send Inquiry
Description
Technical Parameters
Power-On Through the Fire
 

 

The fire alarm control cable carries a mica fire-resistant tape that keeps power and signal alive in high heat, unlike ordinary wire that melts and breaks quickly. The structure works at 950℃ to 1000℃ open flame for over 90 minutes without short circuit, open circuit or burning, maintaining alarm and interlock communication when evacuation and rescue need time.

armoured-control-cablecd223

Fire Tests and Payment

 

armoured-control-cabledadb1

 

Finished units pass fire-resistance, flame, insulation and continuity checks, with tight control over mica-tape wrapping; pre-packing review confirms values before a report. Custom 50% deposit/50% before shipment; reinforced drums, EXW/FOB/DDP, 1-year warranty under normal use.

Low-Smoke Backing and Daily Core
 

The line also carries halogen-free low-smoke flame-retardant behavior, releasing no toxic gas in fire and sparing equipment while supporting evacuation. In normal service, high-purity copper sends alarm signals sensitively and steadily through aging-proof, dust-and-moisture-resistant daily routing between host, detectors, alarms and interlock devices.

armoured-control-cable0b117

 

Alarm and Interlock Loops

Scene one: alarm loops and emergency interlock routing in building fire systems that keep host-detector communication in fire. Scene two: detector and alarm-host links in malls, hospitals and schools that ensure interlock devices start. Scene three: municipal fire companion and interlock lines combining daily stability with emergency continuity.

Fire-Resistant vs Flame Retardant

The two cannot substitute: flame retardance focuses on self-extinguishing and still loses power quickly in fire; fire-resistant keeps circuits energized for alarm and interlock, selected separately by fire design. Outgoing materials support project acceptance documents on request.

 

Product Specifications

 

Parameter

Specification

Fire structure

Mica fire-resistant tape multi-layer protection

Fire capacity

950℃-1000℃ open flame, 90+ minutes continuous

Fire behavior

No short, open circuit or burning; low-smoke halogen-free

Daily conductor

High-purity copper, sensitive and stable

Companion

Fire host, detector, alarm, interlock device

 

 

Hot Tags: fire alarm control cable, China fire alarm control cable manufacturers, suppliers, factory, Copper Control Cable, Instrument Signal Cable, moving control cables, multicore electrical control cables, valve control cables, water resistant control cables

Send Inquiry